OVERVIEW OF PRODUCTS
- NT™ Pressure Transducers, Single-port, Model 4150
- NT™ Pressure Transducers, Single-port, Model 4100
- NT™ Pressure Transducers, Flow-through, Model 4210
- NT™ Pressure Transducers, Flow-through, Model 4250
NT™ Pressure Transducers, Single-port, Model 4150
Using an inert sapphire sensor, the NT™ pressure transducer measures vacuum and positive pressure conditions. Constructed without fill fluids or diaphragms, the transducer provides reliability in conditions where other non-metallic sensors fail and offers accuracy to one percent (1%) of the span.
- Hydrofluoric acid and/or vacuum applications
- Provides accurate and reliable inert vacuum measurements using an inert sapphire pressure sensor.
- Measures gas or liquid pressure, allowing you to monitor process conditions for increased safety and system performance.
- 100% functionally tested prior to shipment with an accuracy of 1% of full scale.
- Provides compatibility and easy integration with electronic displays and monitoring systems.
- No moving parts or fill fluids reduce contamination potential.
- Nonmetallic sensing technology provides reliable measurement.
- PTFE, sapphire, and Kalrez® wetted surfaces for high-purity applications.
- Compact design enables easy installation.
- Industry-standard Flaretek® flared port connections reduce entrapment areas, minimize footprint, provide system design flexibility, and simplify installation.
Product Downloads
NT™ Pressure Transducers for Hydrofluoric Acid and Vacuum Applications, Models 4150, 4250
White Paper / Sapphire-based Pressure Transducers for HF Applications
NT® Pressure Transducer for Vacuum Applications
White Paper / Product Reliability Report for Pressure Transducers & Flowmeters
NT™ Pressure Transducers, Single-port, Model 4100
Whether it’s automation, process control, or safety concerns that require pressure measurement, the instrumentation must be clean, accurate, and reliable. To meet the needs of the semiconductor industry, Entegris combines the latest electronic sensing technology and high-purity materials to create leading-edge products that allow for greater control of process variables.
- Provides reliable pressure measurement in high-purity applications, corrosive chemicals, and CMP slurries
- 100% functionally tested prior to shipment with an accuracy of 1% of the full scale
- No moving parts reduce particle generation potential
- PTFE, PFA, CTFE, and Kalrez® wetted surfaces for high-purity applications
- Industry-standard Flaretek® flared port connections reduce entrapment areas, minimize footprint, provide system design flexibility, and simplify installation
Product Downloads
Pressure Transducers, Models 4100, 4210
White Paper / Choosing Instrumentation for Ultrapure Corrosive Fluid Environments
White Paper / Replacing Gauge Protectors & Other Fluid Filled Instruments
NT™ Pressure Transducers, Flow-through, Model 4210
Whether it’s automation, process control or safety concerns that require pressure measurement, the instrumentation must be clean, accurate and reliable. To meet the needs of the semiconductor industry, Entegris combines the latest electronic sensing technology and high purity materials to create leading-edge products that allow for greater control of process variables.
- Provides reliable pressure measurement in high-purity applications, corrosive chemicals and CMP slurries
- 100% functionally tested prior to shipment with accuracy of 1% of full scale
- No moving parts or fill fluids reduce contamination potential
- The flow-through design on model 4210 minimizes dead volume, reducing contamination potential
- PTFE, PFA, CTFE, and Kalrez® wetted surfaces for high-purity applications
- Industry standard Flaretek® flared port connections reduce entrapment areas, minimize footprint, provide system design flexibility and simplify installation
Product Downloads
NT™ Pressure Transducers, Models 4100, 4210
NT™ Pressure Transducers, Flow-through, Model 4250
Using an inert sapphire sensor, the NT™ pressure transducer measures vacuum and positive pressure conditions. Constructed without fill fluids or diaphragms, the transducer provides reliability in conditions where other non metallic sensors fail and offers accuracy to one percent (1%) of span.
- Hydrofluoric acid and/or vacuum applications
- Provides accurate and reliable inert vacuum measurements using an inert sapphire pressure sensor.
- Measures gas or liquid pressure, allowing you to monitor process conditions for increased safety and system performance.
- 100% functionally tested prior to shipment with accuracy of 1% of full scale.
- Provides compatibility and easy integration with electronic displays and monitoring systems.
- No moving parts or fill fluids reduce contamination potential.
- The flow-through design minimizes dead volume, reducing contamination potential.
- Nonmetallic sensing technology provides reliable measurement.
- PTFE, sapphire, and Kalrez® wetted surfaces for high-purity applications.
- Compact design enables easy installation.
- Industry standard Flaretek® flared port connections reduce entrapment areas, minimize footprint, provide system design flexibility and simplify installation.
Product Downloads
NT™ Pressure Transducers for Hydrofluoric Acid and Vacuum Applications, Models 4150, 4250